Fire Obligations in Occupational Health and Safety: A Practical Employer Guide
Regulation

Fire Obligations in Occupational Health and Safety: A Practical Employer Guide

A practical guide to the employer's fire risk assessment, equipment, training, drill and record obligations, with field mistakes and inspection preparation steps.

Yangın Takip EkibiYangın Takip Ekibi
November 3, 20268 min read

Fire obligations under occupational health and safety law require the employer to assess fire risk, take preventive measures, train employees, run drills, have fire equipment checked periodically and keep a record of all of it. The basis is Law No. 6331 on Occupational Health and Safety and the regulations issued under it.

In practice the problem is rarely a lack of knowledge. It is scattering. Extinguisher checks sit with one company, training with another institution, the drill report in a folder, and the risk assessment on a specialist's computer. The manager who has to pull these pieces together on inspection day discovers what is missing that same day.

This article orders the obligations by the flow of the work rather than by the person responsible. It starts with who is responsible for what, then covers risk assessment, equipment checks, training, drills, escape routes and record keeping.

What are the employer's core fire obligations?

The employer's core duty is to ensure the work-related health and safety of employees, and fire is one of the concrete parts of that duty. The law expects the employer to take the measures needed to prevent risks, assess the ones that cannot be prevented and prepare for emergencies. This responsibility stays with the employer even when a specialist or physician has been assigned.

The obligations are generally grouped under these headings:

  • Assessing fire risk and keeping the risk assessment up to date
  • Installing fire fighting, detection and alarm equipment and keeping it in working order
  • Preparing an emergency plan and assigning response teams
  • Training employees on fire and running drills
  • Keeping escape routes and exits usable at all times
  • Documenting and storing all of these activities

A common mistake is to treat this list as a one-time setup. Once the equipment is bought and the plan is written, the job is considered done. The obligation is continuous, though: equipment ages, staff change, the warehouse layout changes and the plan goes stale. That is why an inspector looks at whether a document is current as much as whether it exists.

The purpose of the building also sets the weight of the obligation. A multi-storey hotel and a small workshop do not carry the same fire load. The regulation on the fire protection of buildings and the regulation on emergencies at workplaces set different expectations depending on the structure and the hazard class of the work. Your risk assessment and your OHS specialist settle which provisions apply to your facility.

How is a fire risk assessment carried out?

A fire risk assessment is the process of identifying what can start a fire, what can burn and who could be affected, and then prioritising measures. It is run either inside the general risk assessment or as a separate section that complements it, and it is prepared by a specialist according to the hazard class.

In practice the steps run in this order. First, walk the facility and note the ignition sources: electrical panels, hot work areas, heaters, welding and cutting, kitchen equipment. Next, establish the combustible load: stored packaging, chemicals, fuel, paper and plastic. Third, look at the points where these two can meet and at the people present there. Finally, judge whether the existing measures are sufficient or propose new ones.

The decision criterion is simple: the higher the risk, the sooner the measure. A stack blocking an escape route does not have the same priority as a missing sign. That is why a risk assessment is a ranking tool rather than a checklist.

A common mistake is to write the assessment once and shelve it. It should be revisited when a new machine arrives, when the warehouse layout changes, when the type of work expands, or after a fire or near miss. The legislation also expects renewal at certain intervals and updating when something changes. The hazard class determines the interval, so confirm the exact period with your OHS specialist.

Who is responsible for fire fighting and detection equipment?

Providing fire equipment that is suitable, sufficient and in working order is the employer's responsibility. Purchase and maintenance can be handed to an authorised company, but the party answerable for whether checks were done on time is still the business.

Equipment groups should be tracked separately. For portable extinguishers, refilling, servicing and pressure checks must match the date on the label. Detection and alarm systems need periodic testing of the panel, detectors and sirens. Fire cabinets, hoses, sprinklers and pumps each have their own maintenance routine. Emergency lighting and exit sign batteries need separate attention because these products fail quietly and nobody notices until the power goes out.

A frequent field mistake is to count equipment only by its presence. A cylinder that sits in place with low pressure shows up as present in the register and is useless in practice. Another is to let stored goods block access to the extinguisher. If you cannot reach the equipment, it does not count.

It helps to split the checks in two: a monthly or shift-based visual check, and the periodic maintenance by the authorised company. The facility manager does the visual check: pressure gauge, seal, accessibility, label. Technical servicing and refilling are left to the authorised company. The date and result of both should be recorded.

Are fire training and drills mandatory for employees?

Yes. Fire training and emergency drills are the employer's obligation under the legislation. Training is given before work starts, when the workplace changes, and repeated at intervals; the drill tests whether the emergency plan actually works on site.

Training should aim at helping employees understand the risk in their own work area. What you tell a warehouse worker differs from what you tell an office worker. The content should cover how a fire is reported, where the assembly point is, which extinguisher is used on which type of fire, and when to leave the fire alone and evacuate. The last point matters: the goal is not to turn everyone into a firefighter but to help them make the right decision.

The most valuable output of a drill is the time and the list of problems. How long evacuation took, which door turned out to be locked, who could not be counted, which zones did not hear the alarm: all of this should be written down after the drill and turned into corrective actions. A "went well" report with no problems noted at all invites suspicion.

A common mistake is to give the training once and treat the attendance list as enough. In workplaces with shifts, the night shift is often left out. New starters work untrained until the next group session. The attendance list should show which shift and which person is still missing.

How are emergency teams and fire officers assigned?

Emergency teams are made up of people the employer assigns to take on duties such as fire fighting, rescue, protection, first aid and evacuation during a fire. The number and type of teams depend on the number of employees, the hazard class and the characteristics of the building.

The assignment should be in writing and by name. A line such as "the warehouse team is responsible" does not say who does what. Each duty needs a primary and a backup person, because leave, illness and shift changes mean the planned person is often not there. Assigned people must be trained and know their duties.

As a decision test, ask: if a fire starts here at three in the morning, who does what? If the answer is not a name and an action, the plan is incomplete. A plan should be useful to everyone who reads it; a plan written only to be shown to an inspector cannot be carried out in the first real incident.

A common mistake is to assign once and not update when staff change. The name of someone who left can stay in the plan for years. Reviewing the team list at every staffing change, and at least once a year, largely prevents this.

How are escape routes and fire exits checked?

An escape route is the path along which a person can reach a safe area from where they are during a fire without obstruction. The route must be open, lit, marked and easy to use; locked doors or blocked exits breach the regulation and are among the most serious findings.

Do the check on foot. Walk from the start of the route to the exit and look for these things: is there stacking or temporary storage in the corridor, do doors open outwards without a key, are the direction signs visible, is the emergency lighting on, is the path to the assembly point clear. Every observation should be recorded, because "we looked and there was no problem" does not count as evidence.

Fire doors need their own attention. A wedge used to hold a door open cancels the door's purpose. A door that stops smoke and flames is just a door when it is left open. Whether the door closing devices work should also be on the checklist.

A common mistake is for a temporary arrangement to become permanent. A pallet placed in a corridor in the busy season "for one day" stays for months. The way to prevent this is regular, short inspections; a monthly walk-through catches more problems than an annual audit.

How are fire records and documents kept?

Fire records are the documents showing who carried out each check, service, training and drill, when, and with what result. These records are what prove at inspection that the obligation was met; work that was done but not documented can be treated by an inspector as work that was not done.

You can group the records you need to keep as follows:

  • The risk assessment and its update dates
  • The emergency plan and the team assignment letters
  • Training attendance lists and drill reports
  • Equipment service, refill and test reports
  • Findings and the dates they were closed

A good record has three properties: it is dated, it is tied to a person, and it can easily be linked to the equipment or area concerned. If finding the last refill of one extinguisher means searching three files, the system is not working.

A common mistake is to keep records on paper and in scattered places. Paper gets lost, wears out, and nobody knows who holds it. For multi-site businesses and for fire companies serving customers, the problem multiplies. Keeping records in one place, in date order, with reminders for upcoming service dates spreads inspection preparation across the year and removes the last-minute rush.

What should you check before an inspection?

Inspection preparation means making sure the documents and the site tell the same story. If the document says the extinguisher check was done but a cylinder on site has an old label, the real finding for the inspector is that contradiction.

You can run the preparation in a short sequence. First, collect the documents and check their dates: is anything expired? Then go to the site and see each piece of equipment listed in the documents in its place. Third, walk the escape routes, exits and the assembly point. Finally, ask a few employees what they would do in an emergency. Their answers show whether the training actually worked.

When you find a gap, do not try to hide it; close it and keep the record of closing. A gap with a corrective date is a gap under control. A gap left unrecorded tends to come back.

To learn more about the monetary fines and site closure procedures enforced when audit findings remain unaddressed, read our guide on administrative penalties for fire safety violations.

Conclusion

Fire obligations do not come from a single document. They come from five or six linked jobs running regularly: risk assessment, equipment checks, training, drills, escape routes and records. When one of them slips, the others lose value. The responsible person's job is to see the date of each one and act before the time comes. At Yangın Takip, we provide software that lets fire safety companies track their customers, facilities, inventory and periodic checks in one place.

On construction sites these obligations take a different shape; our guide to fire safety measures on construction sites covers site-specific topics such as hot work permits and temporary electrics.

Related reading

Bring extinguisher and maintenance tracking into one place

Request a short demo for your company and see the system with your own data in a 14-day free trial.

Request a free demo

Frequently Asked Questions

Who can give fire training?

Fire training can be given by an OHS specialist, a workplace physician or other qualified trainers. What matters is that the content fits the workplace's risks and that attendance is recorded.

How often is a fire drill held?

The drill frequency is set in the regulation according to the hazard class and structure of the workplace. It is best to confirm the exact period with your OHS specialist against the current regulation.

Does the employer arrange extinguisher checks?

Yes, keeping the equipment in working order is the employer's responsibility. Servicing and refilling can be done by an authorised company, but the business must be able to show the checks were made on time.

What happens to a workplace that does not meet its fire obligations?

If deficiencies are found at inspection, administrative sanctions can apply. If a fire occurs, the employer's legal and criminal liability can come into play.

Related Posts